Best viewed on a computer. These pages are not yet optimized for phones: some figures and controls may not fit the screen.
Module 05 of 10 All modules
Module 05 · Chapter III · Sampling

Pixel size and Nyquist sampling

The practical rule and the bandwidth rule, a pixel-size calculator for your objective, and what aliasing does to a bar target scanned like a real confocal.

Simulated Siemens star with 72 cycles, 12 µm across, imaged through a 1 AU confocal at NA 1.4. Left of the divider it is recorded with 40 nm pixels: the spokes run cleanly into a grey core of radius 2.04 µm, where the spokes are finer than 178 nm and the optics pass less than 2% contrast. Right of the divider, with 160 nm pixels, the spokes between the core and a four-lobed boundary (3.67 µm along the pixel rows and columns, 2.59 µm on the diagonals) come back as false, curved spokes: aliasing. Use the left and right arrow keys to move the divider.
SIMULATED · A Siemens star imaged through a 1 AU confocal (NA 1.4 oil, 488 nm). Left of the divider: 40 nm pixels; right: 160 nm pixels. Near the centre the spokes are finer than 178 nm, where the optics pass less than 2 % contrast (grey core). Between the core and the orange line the 160 nm pixels are too coarse for the spokes and return false, curved ones: aliasing. The orange boundary bulges along the pixel rows and columns and pulls in on the diagonals, where the square pixel grid can follow finer spokes. On the 40 nm side the boundary (small orange curve) lies inside the grey core, so nothing is left to alias. Drag the divider to compare the same spokes.
1 · The physics

Two pixels per finest period, and which period counts

The optics set how fine a detail reaches the detector; the pixel size sets whether it survives digitization. The Nyquist–Shannon theorem says a signal is captured without loss only if it is sampled at more than twice its highest frequency: more than two pixels per smallest period. Sample more coarsely and fine structures are not merely blurred but aliased: they come back as false, coarser patterns that no processing can undo.[9]

Two conventions are in use, and they differ by about a factor of two. The practical rule in the Zeiss monograph takes the FWHM of the point image as the finest detail and sets the pixel to half of it, ≈ 0.25 λexc/NA. The bandwidth rule used for deconvolution takes the true cut-off of the optical transfer function; for a confocal that gives Δx = λexc/(8 n sin α), about 44 nm at NA 1.4 and 488 nm. The figure shows why both are defensible: at 1 AU almost no contrast survives between the two.[4][10]

On a point scanner the pixel size is set by the zoom and the pixels per line, not by a camera, so it can be matched to any objective. Oversampling costs time and light (module 08) without adding information. Pawley’s 2.3 to 2.8 samples per resolution element (ch. 4) are a safety margin on the same theorem, not a different one; noise, imperfect reconstruction and pixel integration are what make a margin worthwhile.[4][9]

0246810121000500300200150100100%10%1%0.1%spatial frequency (cycles per µm)period (nm)contrast passed confocal, pinhole 1 AUconfocal, pinhole 0.2 AUwidefield (emission only)1 AU: zero at159 nm, then areversed lobepractical rule94 nm pixelsNyquist 188 nmbandwidth rule44 nm pixelsNyquist 87 nm →edge of thepassband, 90 nm1 AU passes < 3% here;0.2 AU up to 12% COMPUTED · NA 1.4 OIL · 488/520 NM
COMPUTED · How much contrast the optics pass at each spatial frequency (sine-wave transfer function, log scale), from the vectorial model at NA 1.4 oil. The bandwidth rule places two pixels per period at the theoretical edge (90 nm); a 1 AU pinhole leaves less than 3 % contrast beyond the practical rule’s Nyquist frequency, a 0.2 AU pinhole up to 12 %. Beyond a dip at 159 nm a 1 AU pinhole passes a faint lobe (sine contrast below 0.3 %) in which bars appear with inverted contrast.
2 · Live model

Scan a bar target at any pixel size

Ten patches of bars, from 500 to 140 nm periods, pass through the computed 1 AU confocal optics and are recorded the way a point scanner records them: each pixel averages along the scan line. Move the pixel size and watch where the recorded stripes stop matching the object; those patches come back with false, longer periods.

Object → optics → pixels, aligned on one axis · SIMULATED · LIVE · 24 µm targetContrast left in each patch, by period · COMPUTED aliased optics: barsbelow 2%under 178 nm bars, after the optics Nyquist: 2 × pixel = 320 nm 6005004003002502001501200%25%50%75%100%bar period (nm), log scale · coarse → finecontrast
Pixel size160 nm
Confocal 1 AU, NA 1.4 oil, 488 nm: practical rule 94 nm, bandwidth rule 44 nm
Pixel size presets
Photon noise
Pixel grid · real bars stay, aliased stripes move
Periods sampled without aliasing> 320 nm
Bar contrast the optics leave at 2 × pixel43%
Strongest false pattern (noise-free contrast)280 → 373 nm · 16%
Signal power that folds back (detail at all scales)6.9%
Pixels per line, 50 µm field313
Light per area, vs 94 nm pixels0.35×

Undersampled: fine bars return as coarse false stripes (280 nm bars → 373 nm); 6.9% of the signal power of a finely detailed specimen folds back. No processing can separate them from real structure afterwards.

SIMULATED / COMPUTED. Target: ten patches of bars with uniform periods from 500 to 140 nm, one per 2.4 µm slot, each a whole number of periods ending on a bar, separated by dark gutters. Blur: the in-focus vectorial confocal point spread function at 1 AU, NA 1.4 oil, 488/520 nm, circular polarisation, applied as its line-spread function (the bars are long along y), on a 2 nm grid. Sampling as on a point scanner that integrates over the pixel dwell (photon counting; some analog systems sample nearer the pixel centre, Pawley ch. 4 fn. 10): each pixel averages the blurred profile along the scan line over its width, one sample per pixel; the grid starts at the left edge of the axis, or half a pixel later. Rows are independent scan lines; photon noise (off by default): 120 photons in the brightest bars, fixed seed. Light per area scales as 1/pixel², at the same dwell time and power. Curves: bar (square-wave) contrast from the model’s transfer function (Coltman series, Coltman 1954, J Opt Soc Am 44:468; checked by direct convolution), and the sine-wave transfer function; once the third harmonic is cut (periods below about 480 nm) bar contrast is 4/π ≈ 1.27 × the sine value. Dots: (max − min)/(max + min) of your noise-free recorded samples over the central 1.6 µm of each slot, orange where the patch aliases; aliased patches are tagged with the period they appear to have, 1/|1/p − k/Δx| with k the nearest integer to Δx/p (patches whose recorded contrast stays below 2 % are not labelled). Profile row: the blurred profile (thin line) and your noise-free samples (steps) over the central 1.4 µm of each patch, each patch stretched to its own range (at least ±5 % of its mean), so faint patterns show their shape, not their size. Folded-back share: the part of the signal power that lies outside the square |fx|, |fy| < 1/(2 × pixel) for a specimen with detail at all scales (2D transfer function squared, optics only, before pixel integration). The 2 % limit at 178 nm is for bars at 1 AU; beyond a dip at 159 nm a faint lobe (bar contrast below 0.4 %) passes with inverted contrast.[20]

3 · Calculator

Your pixel size

Pick your objective, immersion and excitation line for the pixel size that samples it, by either rule, and the pixels per line it takes to cover your field.

Numerical aperture
Immersion
Excitation λ (nm)
Field width
Lateral FWHM, PH ≥ 1 AU (textbook, Zeiss): 0.51 λexc/NA178 nm
Pixel, practical rule: 0.5 × FWHM89 nm
Pixel, bandwidth rule: λexc/(8 NA)44 nm
Pixels per line at that field563 / 1148

Textbook formulas for a pinhole of 1 AU or more (Zeiss monograph; SVI for the bandwidth rule). At NA 1.4 and 488 nm the vectorial model gives a lateral FWHM of 187 nm at 1 AU, against 178 nm from this formula. Practical rule: 89 nm pixels need 563 per line for a 50 µm field; the bandwidth rule (43.6 nm) needs 1,148.

Formulas used in this module

The math, with its sources

Nyquist criterion[9]
Δx <pmin / 2
Δx: pixel size; pmin: smallest period present in the image after the optics. Periods longer than 2Δx are sampled without aliasing.
Practical rule (Zeiss)[4]
Δx ≤ 0.5 × FWHMlat ≈ 0.25 λexc/NA
Uses the FWHM as the finest detail. NA 1.4, 488 nm: 89 nm with the textbook FWHM (178 nm), 94 nm with the model’s 187 nm.
Bandwidth rule, confocal (for deconvolution)[10]
Δx = λexc / (8 n sin α)
sin α = NA/n. NA 1.4 oil, 488 nm: 44 nm. The finest period a confocal passes at all is 1/[2NA(1/λexc + 1/λem)] = 90 nm at 520 nm emission; two pixels per such period, with λem ≈ λexc, give λexc/(8 NA). Widefield equivalent: λem/(4 n sin α).
Apparent (aliased) period
pa = 1 / |1/p − k/Δx|,k = round(Δx/p)
One-dimensional folding of a period p shorter than 2Δx: 250 nm bars recorded with 160 nm pixels look like 444 nm bars.
Pixel size on a point scanner[4]
Δx = field width / pixels per line
The field width shrinks with zoom; the software shows the resulting pixel size.

About the model

The contrast curve is computed for a square-wave target from the model’s transfer function; its fundamental frequency carries most of the contrast. Bar contrast is 1.27 × the sine-wave contrast once the third harmonic is cut (periods below about 480 nm at 1 AU); the curves show both. Real samples contain many frequencies at once, so aliasing shows up as moiré or false texture rather than clean stripes.

At the microscope

Set the zoom and pixels per line so the pixel matches the rule you need: practical for viewing and measuring, bandwidth rule if the data will be deconvolved (including LIGHTNING and Airyscan processing, module 10).

Sampling applies in z as well (module 06).

Check yourself

Why can’t software recover detail lost to undersampling?

References

Numbered as in the full list on the track page. Figures from a manufacturer rather than the literature are identified as such where they are used.

  1. [4]Wilhelm S, Gröbler B, Gluch M, Heinz H. Confocal Laser Scanning Microscopy: Principles. Carl Zeiss Microscopy, Jena, 2010. Part 1, equations (2)–(8); Part 2 (Nyquist theorem, pixel size); Part 3, ‘Details’, p. IV (fluorescence, photobleaching quantum efficiency).
  2. [9]Pawley JB (ed.). Handbook of Biological Confocal Microscopy, 3rd ed. Springer, 2006. Chapter 4 (Pawley, “Points, pixels, and gray levels”) and Chapter 39 (Diaspro et al., “Photobleaching”).
  3. [10]Scientific Volume Imaging. “Nyquist rate” and “Nyquist calculator”, svi.nl.
  4. [20]Richards B, Wolf E. Electromagnetic diffraction in optical systems II. Structure of the image field in an aplanatic system. Proceedings of the Royal Society of London A 253:358–379, 1959.
  5. [31]Coltman JW. The specification of imaging properties by response to a sine wave input. Journal of the Optical Society of America 44:468–471, 1954. doi:10.1364/JOSA.44.000468

Training

These pages are purely to improve your knowledge: practical training on the instrument is not only recommended but mandatory.